Journal of the American Society of Echocardiography
Volume 14, Issue 8 , Pages 821-824, August 2001

Echocardiography-guided pericardiocentesis with probe-mounted needle: Report of 53 cases

Monza and Milano, Italy

From the Cardiology Department (S.M., A.B., P.R., E.C., F.A., F.V.) and the Anesthesia and Intensive Care Department (G.V.), San Gerardo Hospital; and the Cardiology Department (G.O.), S. Luca Hospital, IRCCS, Istituto Auxologico Italiano; Monza (MI), Italy

Abstract 

Fifty-three pericardiocentesis procedures were performed on 48 patients from 1993 to 2000 at our coronary care unit. Percutaneous puncture (anterior thoracic in 43 cases, subxiphoid in 10 cases) was performed at the site closest to the exploring probe, where the largest amount of fluid was detected. A needle carrier supported by a bracket with two fixed angulations was mounted on the probe. The needle was advanced through the tissues and inside the pericardial space under continuous visualization. The procedure was successful in 52 of 53 cases. In 1 case of diagnostic pericardiocentesis, the pericardial space was impossible to reach because of the minimal amount of pericardial fluid. In 1 case of acute tamponade after transcatheter ablation of the atrioventricular node, the pericardial puncture caused a pleural-pericardial shunt with consequent drainage of pericardial fluid into the pleural space and symptom resolution. In 1 case, a transient atrioventricular type III block occurred. Emergency surgical drainage was not required in any of the cases. No puncture of cardiac walls ever occurred in this series of patients. No major complications occurred; the incidence of minor sequelae was lower than the incidence reported by other studies on pericardiocentesis without continuous visualization. Our technique appears to be safe and easy to perform even in the presence of minimal amounts of pericardial fluid. (J Am Soc Echocardiogr 2001;14:821-4.)

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Reprint requests: Stefano Maggiolini, Via Donizetti 106, Cardiology Department, San Gerardo Hospital, Monza, (MI) Italy (E-mail: as.maggio@tin.it).

PII: S0894-7317(01)19260-6

Journal of the American Society of Echocardiography
Volume 14, Issue 8 , Pages 821-824, August 2001