Journal of the American Society of Echocardiography
Volume 21, Issue 8 , Pages 895-898, August 2008

Importance of Transducer Position in the Assessment of Apical Rotation by Speckle Tracking Echocardiography

Department of Cardiology, Thoraxcenter, Erasmus University Medical Center, Rotterdam, The Netherlands.

published online 25 March 2008.

Background

Speckle tracking echocardiography is increasingly used to quantify left ventricular (LV) twist. However, one of the limitations of the assessment of LV twist by speckle tracking echocardiography is the crucial dependence on correct acquisition of a LV apical short-axis. This study sought to assess the influence of transducer position on LV apical rotation measurements.

Methods

The study population consisted of 58 consecutive healthy volunteers (mean age 38 ± 13 years, 25 men). To obtain parasternal short-axis images at the LV apical level, the following protocol was used. From the standard parasternal position (LV and aorta most inline, with the mitral valve tips in the middle of the sector) an as-circular-as-possible short-axis image of the LV apex, just proximal to the level with end-systolic LV luminal obliteration, was obtained by angulation of the transducer (position 1). From this position, the position of the transducer was changed to one (position 2) and two (position 3) intercostal spaces more caudal with subsequent similar transducer adaptations.

Results

In 8 volunteers (14%) parasternal image quality was insufficient for speckle tracking echocardiography. In 13 volunteers (22%) the LV apical short-axis could only be obtained from one transducer position. In the remaining volunteers with two (n = 27) or three (n = 10) available transducer positions, a more caudal transducer position was associated with increased measured LV apical rotation. Mean measured LV apical rotation was 5.2 ± 1.8 degrees at position 1, 7.3 ± 2.6 degrees at position 2 (P < .001), and 8.7 ± 2.2 degrees at position 3 (P < .001 vs position 1 and P < .05 vs position 2).

Conclusion

A more caudal transducer position is associated with increased measured LV apical rotation.

Keywords: Left ventricular rotation, Speckle tracking echocardiography, Transducer position

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0894-7317(08)00065-5

doi:10.1016/j.echo.2008.02.001

Journal of the American Society of Echocardiography
Volume 21, Issue 8 , Pages 895-898, August 2008