Journal of the American Society of Echocardiography
Volume 21, Issue 9 , Pages 1001-1005, September 2008

Measurement of Left Ventricular Mass by Real-Time Three-Dimensional Echocardiography: Validation Against Magnetic Resonance and Comparison with Two-Dimensional and M-Mode Measurements

  • Masaaki Takeuchi, MD

      Affiliations

    • Second Department of Internal Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan
    • Corresponding Author InformationReprint requests: Masaaki Takeuchi, MD, Second Department of Internal Medicine, University of Occupational and Environmental Health, School of Medicine1-1 Iseigaoka, Yahatanishi-ku, Kitakyushu 807-8555 Japan
  • ,
  • Tomoko Nishikage, BS

      Affiliations

    • Department of Cardiology and Internal Medicine, Tane General Hospital, Osaka, Japan
  • ,
  • Victor Mor-Avi, PhD

      Affiliations

    • Noninvasive Cardiac Imaging Laboratory, University of Chicago Medical Center, Chicago, Illinois
  • ,
  • Lissa Sugeng, MD

      Affiliations

    • Noninvasive Cardiac Imaging Laboratory, University of Chicago Medical Center, Chicago, Illinois
  • ,
  • Lynn Weinert, BS

      Affiliations

    • Noninvasive Cardiac Imaging Laboratory, University of Chicago Medical Center, Chicago, Illinois
  • ,
  • Hironi Nakai, BS

      Affiliations

    • Second Department of Internal Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan
  • ,
  • Ivan S. Salgo, MD

      Affiliations

    • Philips Medical Systems, Andover, Massachusetts
  • ,
  • Olivier Gerard, PhD

      Affiliations

    • Philips Medical Systems Research, Paris, France
  • ,
  • Roberto M. Lang, MD

      Affiliations

    • Noninvasive Cardiac Imaging Laboratory, University of Chicago Medical Center, Chicago, Illinois

Background

The recent development of 3-dimensional (3D) surface detection algorithm of the endocardial and epicardial surfaces from real-time 3D echocardiographic (RT3DE) datasets allows direct semiautomated quantification of left ventricular mass (LVM). Our aims were to (1) evaluate the accuracy of RT3DE measurements of LVM using this algorithm against cardiac magnetic resonance (CMR) reference and (2) compare RT3DE LVM with conventional M-mode, 2-dimensional (2D), and RT3DE-guided biplane measurements.

Methods

A total of 205 patients were studied in 2 protocols: (1) RT3DE and CMR imaging was performed on the same day in 55 subjects; (2) in an additional 150 subjects, RT3DE, 2D, and M-mode images were acquired. In both protocols, RT3DE endocardial and epicardial surfaces were semiautomatically identified at end diastole (QLab, Philips Medical Systems, Andover, MA) to calculate LVM. CMR, 2D, and M-mode–derived LVM were obtained using standard techniques.

Results

A significant correlation (r = 0.95) was noted between RT3DE and CMR-derived LVM with a small bias of −2 g. M-mode–derived LVM measurements (175 ± 64 g) were significantly larger than RT3DE LVM (123 ± 39 g, bias: 52 g) with moderate correlation (r = 0.76). No significant differences in LVM were noted between 2D (125 ± 42 g) and RT3DE values (bias: 1.2 g) with good correlation (r = 0.91, P < .001). However, the best correlation was noted between RT3DE and RT3DE-guided biplane LVM values (r = 0.95, P < .001, bias: −4.6 g). Intraobserver, interobserver variability, and test–retest variability of the RT3DE measurements were 9%, 12%, and 6%, respectively.

Conclusion

RT3DE imaging using the 3D surface detection algorithm allows accurate and reproducible measurements of LVM. RT3DE-guided biplane technique can be used as an accurate time-saving alternative in clinical practice.

Keywords: Echocardiography, Left ventricular mass, Magnetic resonance imaging

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Disclosures: Masaaki Takeuchi: Equipment was loaned and software was donated. Roberto M. Lang: Software was donated. Ivan S. Salgo and Olivier Gerard are employees of Philips Medical Systems.

PII: S0894-7317(08)00408-2

doi:10.1016/j.echo.2008.07.008

Journal of the American Society of Echocardiography
Volume 21, Issue 9 , Pages 1001-1005, September 2008