Journal of the American Society of Echocardiography
Volume 23, Issue 7 , Pages 722-725 , July 2010

How Can We Best Image Congenital Heart Defects? Are Two-Dimensional and Three-Dimensional Echocardiography Competitive or Complementary?

  • Shuping Ge, MD

      Affiliations

    • Corresponding Author InformationReprint requests: Shuping Ge, MD, Section of Cardiology/Heart Center for Children, Drexel University College of Medicine/St Christopher's Hospital for Children, 3601 A Street, Philadelphia, PA 19134.

References 

  1. Dekker DL, Piziali RL, Dong E. A system for ultrasonically imaging the human heart in three dimensions. Comput Biomed Res. 1974;7544–7553
  2. Hung J, Lang R, Flachskampf F, Shernan SK, McCulloch ML, Adams DB, et al. 3D echocardiography: a review of the current status and future directions. J Am Soc Echocardiogr. 2007;20:213–233
  3. Huang X, Shen J, Huang Y, Zheng Z, Fei H, Hou Y, et al. En face view of atrial septal defect by two-dimensional transthoracic echocardiography: comparison to real-time three-dimensional transesophageal echocardiography. J Am Soc Echocardiogr. 2010;23:714–721
  4. Belohlavek M, Foley DA, Gerber TC, Greenleaf JF, Seward JB. Three-dimensional ultrasound imaging of the atrial septum: normal and pathologic anatomy. J Am Coll Cardiol. 1993;22:1673–1678
  5. Marx GR, Fulton DR, Pandian NG, Vogel M, Cao QL, Ludomirsky A, et al. Delineation of site, relative size and dynamic geometry of atrial septal defects by real-time three-dimensional echocardiography. J Am Coll Cardiol. 1995;25:482–490
  6. Magni G, Cao QL, Sugeng L, Delabays A, Marx G, Ludomirski A, et al. Volume-rendered, three-dimensional echocardiographic determination of the size, shape, and position of atrial septal defects: validation in an in vitro model. Am Heart J. 1996;132:376–381
  7. Franke A, Kühl HP, Rulands D, Jansen C, Erena C, Grabitz RG, et al. Quantitative analysis of the morphology of secundum-type atrial septal defects and their dynamic change using transesophageal three-dimensional echocardiography. Circulation. 1997;(suppl):96;II-323-7
  8. Nanda NC, Ansingkar K, Espinal M, Jindal A, Puri VV, Aaluri S, et al. Transesophageal three-dimensional echo assessment of sinus venosus atrial septal defect. Echocardiography. 1999;16:835–837
  9. Georgakis A, Radtke WA, Lopez C, Fiss D, Moser C, Vandecker W, et al. Complex atrial septal defect: percutaneous repair guided by three-dimensional echocardiography. Echocardiography. In press.
  10. Vargas-Barrón J, Espinola-Zavaleta N, Romero-Cárdenas A, Roldán FJ, Keirns C, Hernández-Reyes P, et al. Two- and three-dimensional echocardiographic unroofed coronary sinus. J Am Soc Echocardiogr. 2001;14:742–744
  11. Chen CA, Wang JK, Hsu JY, Hsu HH, Chen SJ, Wu MH. Diagnosis of inferior sinus venosus atrial septal defects using transthoracic three-dimensional echocardiography. J Am Soc Echocardiogr. 2010;23:457;e4-6
  12. Magni G, Hijazi ZM, Pandian NG, Delabays A, Sugeng L, Laskari C, et al. Two-and three-dimensional transesophageal echocardiography in patient selection and assessment of atrial septal defect closure by the new DAS-Angel Wings device: initial clinical experience. Circulation. 1997;96:1722–1728
  13. Acar P, Saliba Z, Bonhoeffer P, Aggoun Y, Bonnet D, Sidi D, et al. Influence of atrial septal defect anatomy in patient selection and assessment of closure with the Cardioseal device; a three-dimensional transoesophageal echocardiographic reconstruction. Eur Heart J. 2000;21:573–581
  14. Zhu W, Cao QL, Rhodes J, Hijazi ZM. Measurement of atrial septal defect size: a comparative study between three-dimensional transesophageal echocardiography and the standard balloon sizing methods. Pediatr Cardiol. 2000;21:465–469
  15. Cao Q, Radtke W, Berger F, Zhu W, Hijazi ZM. Transcatheter closure of multiple atrial septal defects. Initial results and value of two- and three-dimensional transoesophageal echocardiography. Eur Heart J. 2000;21:941–947
  16. Acar P, Saliba Z, Bonhoeffer P, Sidi D, Kachaner J. Assessment of the geometric profile of the Amplatzer and Cardioseal septal occluders by three dimensional echocardiography. Heart. 2001;85:451–453
  17. Lodato JA, Cao QL, Weinert L, Sugeng L, Lopez J, Lang RM, et al. Feasibility of real-time three-dimensional transoesophageal echocardiography for guidance of percutaneous atrial septal defect closure. Eur J Echocardiogr. 2009;10:543–548
  18. Taniguchi M, Akagi T, Watanabe N, Okamoto Y, Nakagawa K, Kijima Y, et al. Application of real-time three-dimensional transesophageal echocardiography using a matrix array probe for transcatheter closure of atrial septal defect. J Am Soc Echocardiogr. 2009;22:1114–1120
  19. Downing SW, Herzog WR, McElroy MC, Gilbert TB. Feasibility of off-pump ASD closure using real-time 3-D echocardiography. Heart Surg Forum. 2002;5:96–99
  20. Suematsu Y, Takamoto S, Kaneko Y, Ohtsuka T, Takayama H, Kotsuka Y, et al. Beating atrial septal defect closure monitored by epicardial real-time three-dimensional echocardiography without cardiopulmonary bypass. Circulation. 2003;11(107):785–790
  21. Suematsu Y, Marx GR, Stoll JA, DuPont PE, Cleveland RO, Howe RD, et al. Three-dimensional echocardiography-guided beating-heart surgery without cardiopulmonary bypass: a feasibility study. J Thorac Cardiovasc Surg. 2004;128:579–587
  22. Suematsu Y, Martinez JF, Wolf BK, Marx GR, Stoll JA, DuPont PE, et al. Three-dimensional echo-guided beating heart surgery without cardiopulmonary bypass: atrial septal defect closure in a swine model. J Thorac Cardiovasc Surg. 2005;130:1348–1357
  23. Feigenbaum H. Role of M-mode technique in today's echocardiography. J Am Soc Echocardiogr. 2010;23:240–257335-7
  24. Hlavacek A, Lucas J, Baker H, Chessa K, Shirali G. Feasibility and utility of three-dimensional color flow echocardiography of the aortic arch: the “echocardiographic angiogram”. Echocardiography. 2006;23:860–864
  25. Chen FL, Ge S. Aortopulmonary window demonstrated by real-time 3-dimensional echocardiography and color Doppler. J Am Soc Echocardiogr. 2007;20:1314;e7-8
  26. Ge S, Bu L, Zhang H, Schelbert E, Disterhoft M, Li X, et al. A real-time 3-dimensional digital Doppler method for measurement of flow rate and volume through mitral valve in children: a validation study compared with magnetic resonance imaging. J Am Soc Echocardiogr. 2005;18:1–7
  27. Lu X, Nadvoretskiy V, Klas B, Bu L, Stolpen A, Ayres NA, et al. Measurement of volumetric flow by real-time 3-dimensional Doppler echocardiography in children. J Am Soc Echocardiogr. 2007;20:915–920
  28. Bu L, Munns S, Zhang H, Disterhoft M, Dixon M, Stolpen A, et al. Rapid full volume data acquisition by real-time 3-dimensional echocardiography for assessment of left ventricular indexes in children: a validation study compared with magnetic resonance imaging. J Am Soc Echocardiogr. 2005;18:299–305
  29. Riehle TJ, Mahle WT, Parks WJ, Sallee D, Fyfe DA. Real-time three-dimensional echocardiographic acquisition and quantification of left ventricular indices in children and young adults with congenital heart disease: comparison with magnetic resonance imaging. J Am Soc Echocardiogr. 2008;21:78–83
  30. Lu X, Xie M, Nadvoretskiy V, Klas B, Tomberlin D, Ayres N, et al. How accurately, reproducibly and efficiently can we measure left ventricular indexes in children using m-mode, 2D and 3D echocardiography?. Am Heart J. 2008;155:946–953
  31. Laser KT, Bunge M, Hauffe P, Argueta JR, Kelter-Klöpping A, Barth P, et al. Left ventricular volumetry in healthy children and adolescents: comparison of two different real-time three-dimensional matrix transducers with cardiovascular magnetic resonance. Eur J Echocardiogr. 2010;11:138–148
  32. Grison A, Maschietto N, Reffo E, Stellin G, Padalino M, Vida V, et al. Three-dimensional echocardiographic evaluation of right ventricular volume and function in pediatric patients: validation of the technique. J Am Soc Echocardiogr. 2007;20:921–929
  33. Lu X, Nadvoretskiy V, Bu L, Stolpen A, Ayres N, Pignatelli RH, et al. Accuracy and reproducibility of real-time three-dimensional echocardiography for assessment of right ventricular volumes and ejection fraction in children. J Am Soc Echocardiogr. 2008;21:84–89
  34. Niemann PS, Pinho L, Balbach T, Galuschky C, Blankenhagen M, Silberbach M, et al. Anatomically oriented right ventricular volume measurements with dynamic three-dimensional echocardiography validated by 3-Tesla magnetic resonance imaging. J Am Coll Cardiol. 2007;50:1668–1676
  35. Khoo NS, Young A, Occleshaw C, Cowan B, Zeng IS, Gentles TL. Assessments of right ventricular volume and function using three-dimensional echocardiography in older children and adults with congenital heart disease: comparison with cardiac magnetic resonance imaging. J Am Soc Echocardiogr. 2009;22:1279–1288
  36. Lu X, Xie M, Wu S, Carr M, Chung T, Taylor M, et al. Quantification of pulmonary regurgitation in repaired tetralogy of Fallot by contrast enhanced real-time 3-dimensional echocardiography. J Am Soc Echocardiogr. 2008;21:604
  37. Soriano BD, Hoch M, Ithuralde A, Geva T, Powell AJ, Kussman BD, et al. Matrix-array 3-dimensional echocardiographic assessment of volumes, mass, and ejection fraction in young pediatric patients with a functional single ventricle: a comparison study with cardiac magnetic resonance. Circulation. 2008;117:1842–1848
  38. Fu M, Choi G, Xie M, Wu J, Carlos W, Morris S, et al. Quantitative real-time 3D echocardiography predicts adverse outcomes in functional single ventricle patients. J Am Soc Echocardiogr. 2010;23:B54
  39. Raedle-Hurst TM, Mueller M, Rentzsch A, Schaefers HJ, Herrmann E, Abdul-Khaliq H. Assessment of left ventricular dyssynchrony and function using real-time 3-dimensional echocardiography in patients with congenital right heart disease. Am Heart J. 2009;157:791–798
  40. Veeram Reddy SR, Du W, Zilberman MV. Left ventricular mechanical synchrony and global systolic function in pediatric patients late after ventricular septal defect patch closure: a three-dimensional echocardiographic study. Congenit Heart Dis. 2009;4:454–458

 Dr Ge is supported by Scientist Development Award 0435319N from the American Heart Association (Dallas, Texas).

PII: S0894-7317(10)00455-4

doi: 10.1016/j.echo.2010.05.018

Journal of the American Society of Echocardiography
Volume 23, Issue 7 , Pages 722-725 , July 2010